RO beta ∙ Type 2 (Pure Water) - 500-1100L/h

RO beta

Type 2 (Pure Water) from Tap Water

The Reliable Ultrapure Water Supply for Entire Buildings


The RO beta is modular-designed, providing high flexibility to adapt to your specific needs from 500 to 1100L/h. 


All components are mounted on a space-saving frame.


Designed for a maximum service life and operational safety.


RO beta systems are built with highest quality components to provide the maximum water quality while maintaining latest industrial standards.

RO beta

Type 2 (Pure Water) from Tap Water


The Reliable Ultrapure Water Supply for Entire Buildings


The RO beta is modular-designed, providing high flexibility

to adapt to your specific needs from 500 to 1100L/h. 


All components are mounted on a space-saving frame.


Designed for a maximum service life and operational safety.


RO beta systems are built with highest quality components

to provide the maximum water quality while maintaining latest industrial standards.

Innovative User Interface
  • Large, Intuitive Touch Screen

    10.1" high-resolution touch display with easy to use menu, automatic temperature compensation, alarm history, alarm output, different languages and various programmable options.


    Line diagrams for all operating values.

  • Smart Monitoring

    All values are permanently supervised and diplayed in a simplified flow diagram. 


    Further to the general information like conductivity and temperature, your RO alpha system monitors several parameters like pressure and flowrate and shows whenever a value is out of specification. 


    This guarantees an optimal performance.

  • Option - Remote Monitoring

    Ethernet and WIFI connection for remote monitoring

    Modbus-TCP interface for all operating values

    Alarm reports and status reports by e-mail, including line diagrams


   Innovative User Interface
  • Large, Intuitive Touch Screen

    10.1" high-resolution touch display with easy to use menu, automatic temperature compensation, alarm history, alarm output, different languages and various programmable options.


    Line diagrams for all operating values.

  • Smart Monitoring

    All values are permanently supervised and diplayed in a simplified flow diagram. 


    Further to the general information like conductivity and temperature, your RO alpha system monitors several parameters like pressure and flowrate and shows whenever a value is out of specification. 


    This guarantees an optimal performance.

  • Option - Remote Monitoring

    Ethernet and WIFI connection for remote monitoring

    Modbus-TCP interface for all operating values

    Alarm reports and status reports by e-mail, including line diagrams


 Intelligent Features
  • Reliable Operation

    Highest quality parts and components ensure best possible water quality and avoid downtime. Sensors protect the system from dry running.  

  • Long-lasting Prefiltration

    An integrated prefilter protects the RO membrane from impurities in the feed water.

  • Cost- and Water-saving Concentrate Recycling

    The concentrate, which is normally discharged directly into the drain, is recirculated to minimise the waste water.

  • Economical EDI

    The ion exchange beds in the EDI cell are regenerated continuously so that they do not exhaust in the same way as common ion exchangers.  An EDI unit may operate for many years before a replacement is required. Typically product water resistivity of >15 MΩ.cm is consistently achieved using this process. This technology will increase the lifetime of the final polishing cartridge significantly and also deliver more consistent purity than single-bed ion-exchange systems that may release weakly bound ions as the media exhausts. The EDI module also reduce the release of organic impurities. This helps to lower your operating costs.

  • Permeate Circulation

    The permeate is circulated depending on the conductivity to extend the lifetime of the EDI module and subsequent periphery and to guarantee a constant water quality.

 Intelligent Features
  • Reliable Operation

    Highest quality parts and components ensure best possible water quality and avoid downtime. Sensors protect the system from dry running.  

  • Long-lasting Prefiltration

    An integrated prefilter protects the RO membrane from impurities in the feed water.

  • Cost- and Water-saving Concentrate Recycling

    The concentrate, which is normally discharged directly into the drain, is recirculated to minimise the waste water.

  • Economical EDI

    The ion exchange beds in the EDI cell are regenerated continuously so that they do not exhaust in the same way as common ion exchangers.  An EDI unit may operate for many years before a replacement is required. Typically product water resistivity of >15 MΩ.cm is consistently achieved using this process. This technology will increase the lifetime of the final polishing cartridge significantly and also deliver more consistent purity than single-bed ion-exchange systems that may release weakly bound ions as the media exhausts. The EDI module also reduce the release of organic impurities. This helps to lower your operating costs.

  • Permeate Circulation

    The permeate is circulated depending on the conductivity to extend the lifetime of the EDI module and subsequent periphery and to guarantee a constant water quality.

   Specifications
Specifications
Feed water requirements
Feed water quality Softened tap water
Conductivity @ 25°C < 2000µS/cm
Total organic carbon (TOC) < 1ppm
Inlet pressure 1 - 6bar
Temperature 5 - 35°C
Pure water specifications
Performance 500L/h, 800L/h or 1100L/h
RO retention rate > 99% salts, germs and bacteria
Residual conductivity 0.06 - 1 µS/cm
Typ. residual conductivity 0.1 µS/cm
TOC value < 30ppb
Silicate reduction > 99%
WCF rate 75% (adjustable)

Dimensions

Feed water requirements
Feed water quality Softened tap water
Conductivity @ 25°C < 2000µS/cm
Total organic carbon (TOC) < 1ppm
Inlet pressure 1 - 6bar
Temperature 5 - 35°C
Pure water specifications
Performance 500L/h, 800L/h or 1100L/h
RO retention rate > 99% salts, germs and bacteria
Residual conductivity 0.06 - 1 µS/cm
Typ. residual conductivity 0.1 µS/cm
TOC value < 30ppb
Silicate reduction > 99%
WCF rate 75% (adjustable)